Changes

Line 137: Line 137:  
[[image:28042011_2.jpg|possibly, Rossi modified the heating power, when journalist Mats Lewan was returning from another room (picture: sreenshot from a video of Mats Lewan)|thumb]]
 
[[image:28042011_2.jpg|possibly, Rossi modified the heating power, when journalist Mats Lewan was returning from another room (picture: sreenshot from a video of Mats Lewan)|thumb]]
 
The days 19 and 28 of april, two further tests were performed in presence of swedish journalist Mats Lewan (Nyteknik). The apparatus was heating water and seemed to produce some steam on some occasion. According to Lewan, heating power was only 315 W. Rossi claimed, that heat produced would amount to more than 2 kW. There is no published report so far. Lewan released two pdf file relating to the tests.([http://www.nyteknik.se/incoming/article3166567.ece/BINARY/Report+test+of+E-cat+19+April+2011.pdf] [http://www.nyteknik.se/incoming/article3166569.ece/BINARY/Report+test+of+E-cat+28+April+2011.pdf]). He made also a video of the test of 28th of april.<ref>http://www.nyteknik.se/nyheter/energi_miljo/energi/article3166451.ece</ref>.  
 
The days 19 and 28 of april, two further tests were performed in presence of swedish journalist Mats Lewan (Nyteknik). The apparatus was heating water and seemed to produce some steam on some occasion. According to Lewan, heating power was only 315 W. Rossi claimed, that heat produced would amount to more than 2 kW. There is no published report so far. Lewan released two pdf file relating to the tests.([http://www.nyteknik.se/incoming/article3166567.ece/BINARY/Report+test+of+E-cat+19+April+2011.pdf] [http://www.nyteknik.se/incoming/article3166569.ece/BINARY/Report+test+of+E-cat+28+April+2011.pdf]). He made also a video of the test of 28th of april.<ref>http://www.nyteknik.se/nyheter/energi_miljo/energi/article3166451.ece</ref>.  
 +
 +
Again, the yellow metering pump "LMI P18" was used. This time however, the flow rate was claimed to be between 63 and 68 ml/min (according to the experiment). These values are compatible with the data sheet of the pump. The stroke frequency was 32 strokes/min. Using a stroke volume of 2 ml (maximum possible), the pump would reach the same value (64 ml/min), confirming the value claimed by observing Lewan. Lewan checked the water flow by measuring water weight differences in particular periods of time. 
 +
 +
It remains unclear, whether the heating power was constant 315 Watt. Lewan checked the total power once at the beginning of the experiment with a clamp amperemeter (1.6 A). When the journalist was in another romm filming a black outlet hose, and was turning the camera, it could be seen, that Rossi was touching the blue power control box. He could have modified the heating power.
    
A further experiment, allegedly planned for April 21, 2011<ref>http://energycatalyzer.blogspot.com/2011/04/rossi-brings-e-cat-to-stockholm-royal.html</ref>, where the E-Cat would have been given to the Swedish scientists Sven Kullander and Hanno Essén of University Uppsala for testing, was denied in afterwards by Rossi.<ref>http://energycatalyzer.blogspot.com/2011/04/andrea-rossi-no-e-cat-test-at-uppsala.html</ref>
 
A further experiment, allegedly planned for April 21, 2011<ref>http://energycatalyzer.blogspot.com/2011/04/rossi-brings-e-cat-to-stockholm-royal.html</ref>, where the E-Cat would have been given to the Swedish scientists Sven Kullander and Hanno Essén of University Uppsala for testing, was denied in afterwards by Rossi.<ref>http://energycatalyzer.blogspot.com/2011/04/andrea-rossi-no-e-cat-test-at-uppsala.html</ref>
143

edits